Low voltage Speed Control


Index of Speed Control

B-LV12 MAX  20A(250W)
B-LV24 MAX  20A(500W)
  • Using over 10A, please with cooling fan

Usage and functions :

  • When S4、S5 control the ON/OFF, the voltage output by M+, M- will be cut off immediately.
  • Once the control has been stopped working for long time, please turn off the power.
  • The voltage (0-9VDC) of speed control can replace potential counter and control. Please connected across V2(+) and V1(-).
  • Please install signal isolator, when it controlled by voltage, it will prevent the interference of potential difference.
  • When it is controlled by voltage, MAX cannot work.
  • LV(Input of Minimum voltage)(12V)LV≤9.5V, (24V)LV≤19V
  • Green light:Power light
  • Yellow light:The input voltage less than 80% the yellow light will light up.
  • Red light:When the electric current overload, please press the Reset back.

Setting of Property Adjustment :

  • Min (Minimum rotation rate): 30% MAX (Maximum rotation rate):70%
  • Accel (Acceleration): 50% LV (Minimun input low voltage): 80%
  • CL (Electric current adjustment): 50%

Range Property Adjustment :

  • Electrical current set (%)........................................................................150-200
  • Accelerating time (0-fully load) (second)....................................................0.5-4.0
  • Adjustment range of minimum rotation rate (% fully load)...............................0-30
  • Adjustment range of maximum rotation rate (% fully load)...........................50-100
  • Input of minimum voltage................................................................................80
  • Range of rotation rate (ratio)........................................................................30:1
  • The highest permission of fully rotation ambient temperature (°C°/F)............42/113